Delivering Air Conditioning Excellence

Light Commercial R32

New for 2018. Hitachi’s Light Commercial range of Air Conditioning equipment bridges the gap between domestic and commercial product, offering high efficiencies, quality engineering and stylish design.

These products are targeted at the Light Commercial market such as small to medium sized commercial office developments, restaurants and retail applications.

RAK-50_60PPD_louver
High Wall R32

The new Light Commercial Wall Mounted system offers high efficiencies, high heating capacities and advanced features including Human Sensor as standard

Features and Benefits

  • Human sensor (standard): The unit adapts its temperature settings depending on people absence or presence. When the presence of people is not detected for 20 minutes, the set temperature is automatically shifted for energy saving. If nobody is in the room for 60 minutes, the set temperature is shifted further.
  • Cooling & Heating capacities from 5.0kW to 8.0kW
  • High heating capacities at low temperatures
  • All Hitachi’s units offer high seasonal efficiencies, with models in the Light Commercial Cassette range achieving up to SEER A++ 6.20/SCOP A+ 4.40
  • 4 WAY SWING: Horizontal and Vertical Auto-Swing
  • Ideal for small to medium sized commercial areas such as offices, restaurants and retail
  • Server Room Application: Cooling in ambients of -15°C
  • NEW 24-hour, 7-day infra red remote controller with ‘view energy usage’ option as standard
  • Connects to Hitachi’s H-LINK II system via PSC-6RAD adapter providing compatibility with CS Net web
  • Optional, advanced Hard Wired Controller
  • Optional Hi-Kumo WiFi Solution
  • Optional Eco-Sensor: The unit adapts its temperature settings depending on people absence or presence
  • Pre-charged to 30m: (Full Piping Length)
  • Cooling to -15°C
  • Heating to -15°C
  • Lower GWP R32 Refrigerant
INDOORUnitRAK-50PPDRAK-60PPDRAK-70PPD
Nominal capacity adjustable no
Nominal Cooling capacity (min - max)kW5.00 (1.20- 5.80) 6.00 (1.20 - 6.50) 7.00 (1.50 - 8.00)
Cooling sensible capacity kW
Nominal Heating capacity (min - max)kW6.00 (1.20- 6.80) 7.00 (1.20 - 8.00) 8.00 (1.50 - 8.50)
Noise level cooling (sound pressure) (SL / L / M / H)dB(A)26/33/39/4730/33/42/4830/35/42/47
Noise level heating (sound pressure) (SL / L / M / H)dB(A)26/33/39/4733/34/42/4930/36/42/47
Noise level (sound power) *match with Fiche/ Eurovent/Product InfodB(A)60
Air flow cooling mode (SL / L / M / H)m 3 /h310/410/570/720310/410/570/720510/630/870/1020
Air flow heating mode (SL / L / M / H) m 3 /h350/460/640/800350/460/640/800510/630/870/1080
Fan MotorW303038
Dehumidificationl/h2.82.84.8
Included drain pump *for RAI/RADyes/nono
Max. height available for drain pump (RAD/RAI only)cmno
Drain pump pressure lift *for RAI/RADcmno
Static pressure switch at High(L / M / H) *for RADPa (m3/h)no
Dimensions (H x W x D)mm 300 x 900 x 230 300 x 900 x 230300 x 1100 x 260
Weight *must match with Packing data informationkg11.511.515
Panel weight *for RAIkg-
Panel dimensions (H x W x D) *for RAImm-
Colour (Munsell Code)White (N9.5)
Condensate Drainmmφ16mm
Panel reference---
Color of the panel (RAL)---
Running current (C/H) *for single split indoor&outdoor must be matchedA---
Power supplyV220 - 240V / 1Ph / 50/60Hz 220 - 240V / 1Ph / 50/60Hz 220 - 240V / 1Ph / 50/60Hz
Cable section (interconnection/*if power supply is connected to indoor)mm²1.50x 3+EARTH/-1.50x 3+EARTH/-1.50x 3+EARTH/-
Piping diameter (Liq / Gas)Inch1/4" / 1/2"1/4" / 1/2"1/4" / 5/8"
Drain diameter (ext)mmφ16mmφ16mmφ16
Remote control (standard/optional) *StandardNANANA
OptionalSPX-RCKA2 / SPX-RCDB / SPX-WKT3SPX-RCKA2 / SPX-RCDB / SPX-WKT3SPX-RCKA2 / SPX-RCDB / SPX-WKT3
Filter
ACL Filter Standard (Material & Accessory code)Active Carbon / SPX-CFH25Active Carbon / SPX-CFH25Active Carbon / SPX-NTW4
ACL Filter Standard Dimensions (H x W x D)mm48x243x548x243x538x248x5
ACL Filter Optional (Material - Accessory code)SPX-CFH25SPX-CFH25SPX-CFH25
Pre-filter Standard MaterialNORMALNORMALNORMAL
Pre-filter Optional (Material & Accessory code)---
OUTDOOR UNITRAC-50NPDRAC-60NPDRAC-70NPD
Minimum / Maximum indoor units connectable (for MULTI only)nonono
Minimum / Maximum connected indoor capacity (for MULTI only) nonono
Nominal Cooling capacity (min - max) *for single split indoor&outdoor must be matchedkW 5.00 (1.20- 5.80) 6.00 (1.20 - 6.50) 7.00 (1.50 - 8.00)
Nominal Heating capacity (min - max) *for single split indoor&outdoor must be matchedkW 6.00 (1.20- 6.80) 7.00 (1.20 - 8.00) 8.00 (1.50 - 8.50)
Nominal cooling power input (min - max)kW 1,420 (300 ~ 2,500)1,710 (300 ~ 2,650)2,000 (500 ~ 2,700)
Nominal heating power input (min - max)kW 1,500 (300 ~ 2,650)1,840 (300 ~ 2,650)2,100 (500 ~ 2,800)
Heating at -7C (Full load without defrost)kW 4.85.66.6
Heating at -7C (Full load with defrost)kW 4.24.85.8
EER / COP (T1/H1 condition) 3.52 / 4.003.51 / 3.803.50 / 3.81
SEER / SCOP *average climate7.30 / 4.606.50 / 4.207.00 / 4.60
Energy class (SEER/SCOP) A++/A++A++/A+A++/A++
Noise level cooling (sound pressure) dB(A) 505052
Noise level heating (sound pressure) dB(A) 535354
Noise level - In/Out (sound power) dB(A) 60/6560/6560/67
Air flow (Cooling / Heating) m 3 /h2160 / 21602160 / 21602700 / 2700
Dimensions (H x W x D)mm750×850×298750×850×298800×850×298
Weightkg505052
Colour (Munsell Code)Beige (5Y7/2)Beige (5Y7/2)Beige (5Y7/2)
Power supplyV/Ph/Hz220 - 240V / 1Ph / 50/60Hz 220 - 240V / 1Ph / 50/60Hz 220 - 240V / 1Ph / 50/60Hz
Recommended fuse sizeA202020
Starting current(rated current of COOL/HEAT whichever higher for inverter)A101010
Running current (C/H) *for single split indoor&outdoor must be matchedA---
Cable section (power)mm²2.50x 2+EARTH2.50x 2+EARTH2.50x 2+EARTH
Interconnection between indoor unit and outdoor unitmm²1.50x 3+EARTH1.50x 3+EARTH1.50x 3+EARTH
Piping diameter (Liq / Gas) *for single split indoor&outdoor must be matchedInch1/4" / 1/2"1/4" / 1/2"1/4" / 5/8"
Minimum piping lengthm333
Maximum piping length / height differencem30 / 2030 / 2030 / 20
Current quantity of refrigerantkg / TeqCO ²1.50 / 1.01251.50 / 1.01251.60 / 1.08
Chargeless length / Additional refrigerant chargem / g/m303030
Working range (cooling / heating) °C -15℃ - 46℃ /-15℃ - 46℃ /-15℃ - 46℃ /
°C -15℃ - 24℃-15℃ - 24℃-15℃ - 24℃
Refrigerant / GWPR32 / 675R32 / 675R32 / 675
Condenser FanPropeller FanPropeller FanPropeller Fan
CompressorTypeRotaryROTARYROTARY
Oil TypeACS68RACS68RACS68R
Oil Charge l580±5580±5580±5
Coil resistance1.579Ω ±7% at 75℃1.579Ω ±7% at 75℃1.579Ω ±7% at 75℃
Quantity111
RAD-PPD_Lo
Ducted R32

This compact concealed ducted solution is low height (270mm) with high performance (150Pa ESP). It allows flexibility and individual zone control of each interior space to maintain consistent temperatures and airflow distribution.

Features and Benefits

  • Compact: 270mm Max Height
  • Low Sound Level: 29dBA
  • Drain Pump: Included
  • Cooling & Heating capacities from 5.0kW to 8.0kW
  • High heating capacities at low temperatures
  • All Hitachi’s units offer high seasonal efficiencies, with models in the Light Commercial Ducted range achieving up to SEER A++ 6.20/SCOP A+ 4.40
  • Ideal for small to medium sized commercial areas such as offices, restaurants and retail
  • NEW 24-hour, 7-day infra red remote controller with ‘view energy usage’ option as standard
  • Connects to Hitachi’s H-LINK II system via PSC-6RAD adapter providing compatibility with CS Net web
  • Optional, advanced Hard Wired Controller
  • Optional Hi-Kumo WiFi Solution
  • Pre-charged to 30m: (Full Piping Length)
  • Cooling to -15°C
  • Heating to -15°C
  • Lower GWP R32 Refrigerant
INDOORUnitRAD-50PPDRAD-60PPDRAD-70PPD
Nominal capacity adjustable no
Nominal Cooling capacity (min - max)kW5.00 (1.20-5.80)6.00 (1.20-6.50)7.0 (1.50-8.00)
Cooling sensible capacity kW
Nominal Heating capacity (min - max)kW6.00 (1.20-6.80)7.00 (1.20-8.00)8.0 (1.50-8.50)
Noise level cooling (sound pressure) (SL / L / M / H)dB(A)29/32/35/3929/32/35/3929/32/35/39
Noise level heating (sound pressure) (SL / L / M / H)dB(A)29/32/35/4029/32/35/4029/32/35/40
Noise level (sound power) *match with Fiche/ Eurovent/Product InfodB(A)53
Air flow cooling mode (SL / L / M / H)m 3 /h350/540/800/1140350/540/800/1140350/540/800/1140
Air flow heating mode (SL / L / M / H) m 3 /h350/540/800/1140350/540/800/1140350/540/800/1140
Fan MotorW180
Dehumidificationl/h2.82.84.8
Included drain pump *for RAI/RADyes/noyes
Max. height available for drain pump (RAD/RAI only)cm50
Drain pump pressure lift *for RAI/RADcm30
Static pressure switch at High(L / M / H) *for RADPa (m3/h)50/100/150
Dimensions (H x W x D)mm270x900x720270x900x720270x900x720
Weight *must match with Packing data informationkg353535
Panel weight *for RAIkg-
Panel dimensions (H x W x D) *for RAImm-
Colour (Munsell Code)-
Condensate Drainmm-
Panel reference---
Color of the panel (RAL)---
Running current (C/H) *for single split indoor&outdoor must be matchedA---
Power supplyV220 - 240V / 1Ph / 50/60Hz 220 - 240V / 1Ph / 50/60Hz 220 - 240V / 1Ph / 50/60Hz
Cable section (interconnection/*if power supply is connected to indoor)mm²1.50x 3+EARTH/-1.50x 3+EARTH/-1.50x 3+EARTH/-
Piping diameter (Liq / Gas)Inch1/4" / 1/2"1/4" / 1/2"1/4" / 5/8"
Drain diameter (ext)mmφ32mmφ32mmφ32mm
Remote control (standard/optional) *StandardNANANA
OptionalSPX-RCKA1 / SPX-RCDA / SPX-WKT3SPX-RCKA1 / SPX-RCDA / SPX-WKT3SPX-RCKA1 / SPX-RCDA / SPX-WKT3
Filter
ACL Filter Standard (Material & Accessory code)---
ACL Filter Standard Dimensions (H x W x D)mm---
ACL Filter Optional (Material - Accessory code)---
Pre-filter Standard MaterialNORMALNORMALNORMAL
Pre-filter Optional (Material & Accessory code)---
OUTDOOR UNIT   
Minimum / Maximum indoor units connectable (for MULTI only)nonono
Minimum / Maximum connected indoor capacity (for MULTI only) nonono
Nominal Cooling capacity (min - max) *for single split indoor&outdoor must be matchedkW 5.00 (1.20-5.80)6.00 (1.20-6.50)7.0 (1.50-8.00)
Nominal Heating capacity (min - max) *for single split indoor&outdoor must be matchedkW 6.00 (1.20-6.80)7.00 (1.20-8.00)8.0 (1.50-8.50)
Nominal cooling power input (min - max)kW 1,420 (300 ~ 2,500)1,710 (300 ~ 2,600)2,110 (500 ~ 2,700)
Nominal heating power input (min - max)kW 1,570 (300 ~ 2,650)1,840 (300 ~ 2,650)2,200 (500 ~ 2,800)
Heating at -7C (Full load without defrost)kW 4.85.56.2
Heating at -7C (Full load with defrost)kW 4.255.5
EER / COP (T1/H1 condition) 3.52 / 3.823.51 / 3.803.32 / 3.64
SEER / SCOP *average climate6.20 / 4.006.20 / 4.006.10 / 4.00
Energy class (SEER/SCOP) A++/A+A++/A+A++ /A+
Noise level cooling (sound pressure) dB(A) 505050
Noise level heating (sound pressure) dB(A) 535353
Noise level - In/Out (sound power) dB(A) 53/6553/6553/65
Air flow (Cooling / Heating) m 3 /h
Dimensions (H x W x D)mm
Weightkg
Colour (Munsell Code)
Power supplyV/Ph/Hz
Recommended fuse sizeA
Starting current(rated current of COOL/HEAT whichever higher for inverter)A
Running current (C/H) *for single split indoor&outdoor must be matchedA
Cable section (power)mm²
Interconnection between indoor unit and outdoor unitmm²
Piping diameter (Liq / Gas) *for single split indoor&outdoor must be matchedInch
Minimum piping lengthm
Maximum piping length / height differencem
Current quantity of refrigerantkg / TeqCO ²
Chargeless length / Additional refrigerant chargem / g/m
Working range (cooling / heating) °C
°C
Refrigerant / GWP
Condenser Fan
CompressorType
Oil Type
Oil Charge l
Coil resistance
Quantity
RAI-PPD_1
Mini Cassette R32

The compact 600 x 600 cassette fits perfectly into a standard ceiling module allowing for a quick and easy installation.

Features and Benefits

  • Compact: The most compact cassette of the market 600 x 600mm. The new panel is fully embedded within one ceiling tile. Lights or other installations are able to be installed in the adjoining ceiling tiles
  • Human sensor (standard)
  • Coanda effect: extend conditioned airflow across the room
  • Cooling & Heating capacities from 5.0kW to 7.0kW
  • High heating capacities at low temperatures
  • Each louver of the cassette can be individually controlled for a comfortable air flow and an adaptability to all room configurations.
  • All Hitachi’s units offer high seasonal efficiencies, with models in the Light Commercial Cassette range achieving up to SEER A++ 6.20/SCOP A+ 4.40
  • Built-in condensate drain pump
  • Ideal for small to medium sized commercial areas such as offices, restaurants and retail
  • NEW 24-hour, 7-day infra red remote controller with ‘view energy usage’ option as standard
  • Connects to Hitachi’s H-LINK II system via PSC-6RAD adapter providing compatibility with CS Net web
  • Optional, advanced Hard Wired Controller
  • Optional Hi-Kumo WiFi Solution
  • Optional Eco-Sensor: The unit adapts its temperature settings depending on people absence or presence
  • Pre-charged to 30m: (Full Piping Length)
  • Cooling to -15°C
  • Heating to -15°C
  • Lower GWP R32 Refrigerant
INDOORUnitRAI-50PPDRAI-60PPD
Nominal capacity adjustable no
Nominal Cooling capacity (min - max)kW5.00 (1.20- 5.80) 6.00 (1.20 - 6.50)
Cooling sensible capacity kW
Nominal Heating capacity (min - max)kW6.00 (1.20- 6.80) 7.00 (1.20 - 8.00)
Noise level cooling (sound pressure) (SL / L / M / H)dB(A)29/35/39/4329/35/39/43
Noise level heating (sound pressure) (SL / L / M / H)dB(A)30/36/40/4430/36/40/44
Noise level (sound power) *match with Fiche/ Eurovent/Product InfodB(A)56
Air flow cooling mode (SL / L / M / H)m 3 /h390/540/630/720390/540/630/720
Air flow heating mode (SL / L / M / H) m 3 /h450/600/690/780450/600/690/780
Fan MotorW57
Dehumidificationl/h2.83.8
Included drain pump *for RAI/RADyes/noyes
Max. height available for drain pump (RAD/RAI only)cm30.4
Drain pump pressure lift *for RAI/RADcm11.5
Static pressure switch at High(L / M / H) *for RADPa (m3/h)yes
Dimensions (H x W x D)mm285x570x570
Weight *must match with Packing data informationkg17
Panel weight *for RAIkg2.8
Panel dimensions (H x W x D) *for RAImm30x620x620
Colour (Munsell Code)-
Condensate Drainmm-
Panel reference P-AP56NAMS P-AP56NAMS
Color of the panel (RAL)-
Running current (C/H) *for single split indoor&outdoor must be matchedA-
Power supplyV220 - 240V / 1Ph / 50/60Hz 220 - 240V / 1Ph / 50/60Hz
Cable section (interconnection/*if power supply is connected to indoor)mm²1.50x 3+EARTH/-1.50x 3+EARTH/-
Piping diameter (Liq / Gas)Inch1/4" / 1/2"1/4" / 1/2"
Drain diameter (ext)mmφ32mmφ32mm
Remote control (standard/optional) *StandardNANA
OptionalSPX-RCKA3 / SPX-RCDB / SPX-WKT3SPX-RCKA3 / SPX-RCDB / SPX-WKT3
Filter
ACL Filter Standard (Material & Accessory code)--
ACL Filter Standard Dimensions (H x W x D)mm--
ACL Filter Optional (Material - Accessory code)--
Pre-filter Standard MaterialNORMALNORMAL
Pre-filter Optional (Material & Accessory code)--
OUTDOOR UNIT  
Minimum / Maximum indoor units connectable (for MULTI only)nono
Minimum / Maximum connected indoor capacity (for MULTI only) nono
Nominal Cooling capacity (min - max) *for single split indoor&outdoor must be matchedkW 5.00 (1.20- 5.80) 6.00 (1.20 - 6.50)
Nominal Heating capacity (min - max) *for single split indoor&outdoor must be matchedkW 6.00 (1.20- 6.80) 7.00 (1.20 - 8.00)
Nominal cooling power input (min - max)kW 1,420 (300 ~ 2,500)1,710 (300 ~ 2,600)
Nominal heating power input (min - max)kW 1,570 (300 ~ 2,650)1,840 (300 ~ 2,650)
Heating at -7C (Full load without defrost)kW 4.85.5
Heating at -7C (Full load with defrost)kW 4.24.8
EER / COP (T1/H1 condition) 3.52/3.823.51 / 3.80
SEER / SCOP *average climate6.20/4.406.20 / 4.40
Energy class (SEER/SCOP) A++/A+A++/A+
Noise level cooling (sound pressure) dB(A) 5050
Noise level heating (sound pressure) dB(A) 5353
Noise level - In/Out (sound power) dB(A) 56/6556/65
Air flow (Cooling / Heating) m 3 /h
Dimensions (H x W x D)mm
Weightkg
Colour (Munsell Code)
Power supplyV/Ph/Hz
Recommended fuse sizeA
Starting current(rated current of COOL/HEAT whichever higher for inverter)A
Running current (C/H) *for single split indoor&outdoor must be matchedA
Cable section (power)mm²
Interconnection between indoor unit and outdoor unitmm²
Piping diameter (Liq / Gas) *for single split indoor&outdoor must be matchedInch
Minimum piping lengthm
Maximum piping length / height differencem
Current quantity of refrigerantkg / TeqCO ²
Chargeless length / Additional refrigerant chargem / g/m
Working range (cooling / heating) °C
°C
Refrigerant / GWP
Condenser Fan
CompressorType
Oil Type
Oil Charge l
Coil resistance
Quantity